A go/no-go gauge is a decision tool. It is designed to answer "is this feature inside its limit?" with a yes or no, and it is deliberately unable to answer "how far inside?". Most arguments about gauge results come from forgetting that distinction.
For a plain or thread plug gauge, the part is acceptable when the GO gauge enters freely through the full length of the feature and the NO-GO gauge does not enter beyond the chamfer, or beyond the small number of turns allowed by the applicable standard for threaded features. Two words carry the weight:
A GO gauge that enters halfway and stops is a fail. The usual causes, in order of frequency:
Recording "partial" without a cause is the same as recording nothing. The useful record is the depth of entry, the condition of the gauge and the part temperature.
GO gauges wear on the flanks and at the leading edge. A worn GO gauge is undersize, so it enters parts that should be rejected; the inspection station then reports a good day while scrap ships. This is the single most expensive failure mode in gauge-based inspection, and it is invisible without a calibration record.
| New gauge | Record the certificate values and the gauge identification before first use. |
| In service | Check at a fixed interval based on cycles, not calendar alone. High-volume stations need shorter intervals. |
| Wear limit reached | Retire or rework to a defined undersize for use as a reference, never return it to inspection. |
Gauge results are defined at a reference temperature, normally 20 degrees C. A part measured straight from a warm moulding press is not the same part. Steel expands about 11 to 12 micro-metres per metre per kelvin; a 30 K difference on a 100 mm feature is roughly 0.035 mm, which is larger than many gauge tolerances. Let the part stabilise, and write the soak time into the work instruction.
Force matters as well. A GO gauge should be offered, not driven. A soft mallet, a press or a tap with the palm converts a marginal part into a passing one and damages the gauge at the same time.
Use the gauge for the verdict, and a measuring instrument for the trend. Mixing the two purposes is how a stable process gets an unnecessary adjustment.
Record gauge ID, certificate due date, part number, cavity, operator, temperature and verdict. Keep rejected parts with the gauge that rejected them until the shift review. If a gauge is found out of tolerance, the parts inspected since its last good check are suspect and must be recalled; that is only possible if the records identify the gauge. The test probe range and the plug and socket gauge range list the standard gauge types and their applications.