2026-11-16

In IEC 60529 and IEC 61032, four probes cover the first IP digit, and they differ in two ways: the shape of the tip and the force with which the probe is applied. Most of the confusion in an IP test house comes from the second difference, because the force is easy to apply approximately and hard to apply exactly, and because the force is what separates a marginal pass from a marginal fail.

The four probes and their forces

CodeProbeForceWhat it represents
IP1XTest probe A, 50 mm sphere50 NThe back of a hand
IP2XTest probe B, jointed finger30 NA finger, with joints
IP3XTest probe C, 2.5 mm pin3 NA tool or a wire
IP4XTest probe D, 1 mm pin1 NA fine wire or a splinter

The forces are not arbitrary. Each is the force a human or a tool of that scale can reasonably apply, and each is applied so the probe presses against the opening rather than being pushed through it. The test is whether the probe touches a hazardous live part, not whether it can be forced in.

The stop face does most of the work

Each probe has a defined stop surface that limits how far it can enter an opening. The 50 mm sphere is limited by its own diameter. The jointed finger is limited by a 50 mm diameter guard behind the fingertip. The pins are limited by a 35 mm guard, and the pin length beyond the guard is what the code specifies.

This is why a worn or modified probe gives the wrong answer even when the force is right. If the guard has been turned down, the pin reaches further into the enclosure and finds live parts that a correct probe would not touch. The failure looks like a product problem and is a probe problem.

  • Check the guard diameter, not just the pin diameter.
  • Check the pin length beyond the guard with a depth micrometer.
  • Check that the guard face is square to the pin; a bent probe has a variable effective length.
  • Check the joint stiffness of the finger probe, since a slack joint lets the tip reach around a corner.

Applying force without cheating

The standard method is to apply the force gradually and hold it, not to tap or push sharply. Three habits make the result repeatable:

  1. Use a force gauge, not a hand. A calibrated push-pull gauge with a peak hold function turns the application into a measurement.
  2. Apply along the natural direction of access. A probe pushed sideways into an opening tests a geometry that does not exist.
  3. Hold for a defined time. A few seconds at full force reveals whether a resilient gasket or a shutter gives way.

Reading the result

The criterion is access to hazardous parts, judged with the probe in place. Three findings are distinct:

  • Touching a live part with the probe tip — a fail at that IP level.
  • Reaching a moving part or a hot surface that the code protects — also a fail, and often missed because the part is not electrical.
  • Entering an opening but stopping at the guard without touching anything — a pass, and worth photographing so the next inspector does not re-open the question.

The insulation barrier on the probe

The finger and pin probes carry an insulating barrier that represents skin that cannot enter the opening. The barrier is not a convenience; it defines the geometry of the test. A probe with a cracked or missing barrier will report contact that a correct probe would not make, and a probe with a conductive extension fitted by an operator will do the opposite.

Inspect the barrier at every use: a crack at the base of the fingertip is the usual failure and is invisible from the front.

The test probe and test finger range lists probes A to D with guard dimensions and force ratings; the catalogue indexes the push-pull gauges used to apply the specified force.