Technical Articles

Drop and Topple to IEC 60068-2-31: Which Face, Which Height, Which Edge

2026-11-17

Dropping a product is easy. Dropping it in a way that predicts field failure is a method, and IEC 60068-2-31 is that method. It does not say "drop it from a metre". It says which faces, which edges, which corners, in which order, and from what height relative to the mass of the specimen.

The sequence matters because the first impact changes the specimen. A corner impact that cracks a moulding makes the following face impact a different test.

What the procedure actually specifies

ElementWhat the clause setsWhy
FacesEach face that can be at the bottom in serviceThe obvious case
EdgesSelected edges, typically the most vulnerableConcentrates energy on a line
CornersSelected cornersConcentrates energy on a point
HeightRelated to mass and to the severity classHeavier specimens from lower heights
ReleaseFree fall, no swing, no rotationA tumbling specimen lands unpredictably
SurfaceSteel plate or concrete, specifiedA wooden floor absorbs the energy

The corner drop is the one that finds moulding defects, because all the energy arrives at a point and travels through the wall thickness. A product that survives six face drops can fail the first corner drop, and that is the intended discrimination, not an accident.

Why the order is part of the test

Run the corner first and the face last, and the face result is contaminated by a crack that started at the corner. Run the face first and the corner may be landing on a deformed edge. The standard fixes an order so that results from different laboratories are comparable, and a report that lists results without the order is not reproducible.

It also means a single failed impact does not stop the sequence automatically. If the failure is a cosmetic crack, the remaining impacts still have to be run, because the question is whether the product remains safe, not whether it remains pretty.

What counts as a failure

  • Exposed live parts. A crack that opens access to a terminal is a safety failure.
  • Loss of dielectric strength. Check insulation resistance after the sequence, not just visually.
  • Loss of function. A display that stops or a relay that sticks is a failure even with no visible damage.
  • Detached parts. A cover that comes off is a failure, and a cover that is retained only by friction is a failure waiting for the second drop.

Setting up so the result means something

Use the release mechanism the standard describes, not a hand. A hand imparts rotation and a small upward component, and the specimen lands on an edge instead of the face. Check the height at the lowest point of the specimen, not at the centre of mass.

Photograph the impact point before and after each drop, and note the ambient temperature: polycarbonate at 5 °C is a different material from polycarbonate at 25 °C, and a winter shipment will find that out. A drop test rig with a guided release and an adjustable height scale removes the operator from the result, and the site index lists the fixtures for edge and corner orientations.

The heights that are actually used

The height in a drop test is chosen from the mass and the severity class, and it lands on a small set of values: 25 mm, 50 mm and 100 mm for equipment that is normally moved by hand, with 1 m reserved for portable hand-held products in many product standards. A 10 kg bench instrument is not dropped from a metre, and applying that height to it tests the floor rather than the product.

The number of impacts follows the same logic. Six faces, three edges and one corner is a common sequence, giving ten impacts and ten chances to crack a moulding. Running one drop and declaring the product robust is a sample of one from a distribution that is not narrow.