Technical Articles

Vibration Sweep to IEC 60068-2-6: 10–55–10 Hz, 2 Hours per Axis

2026-11-17

Most small electrical products are vibration tested with a sweep from 10 Hz to 55 Hz and back, repeated for two hours on each of three axes. The numbers look arbitrary until you notice what they cover: the range where a chassis, a terminal block and a DIN rail all have resonances, and the range a road vehicle excites most strongly.

The test is easy to pass and easy to pass wrongly. A product clamped to a table that flexes at 30 Hz is being tested at 30 Hz by the table, not by the specification.

The parameters and what they change

ParameterTypical valueEffect
Frequency range10 Hz to 55 Hz, or 10 Hz to 150 HzCovers chassis and mounting resonances
AmplitudeDisplacement below the crossover, acceleration aboveThe crossover is where the two are equal
Sweep rateOne octave per minuteToo fast and a sharp resonance is missed
Duration2 hours per axis, 6 hours totalFatigue, not just survival
AxesThree, orthogonalA part can be strong in two directions
MountingAs in service, or on a rigid fixtureDecides what is actually excited

The crossover matters because below it the shaker is displacement-limited and above it acceleration-limited. A specification written only as acceleration will over-test at low frequency; one written only as displacement will destroy the shaker at high frequency.

Find the resonance before you run the sweep

Run a low-level sweep first, at a tenth of the specified amplitude, with an accelerometer on the product as well as on the table. The ratio between the two curves is the transmissibility, and its peak is where the product will be stressed. If the peak is at 32 Hz with a transmissibility of 8, the 2 hour run is really a 16 hour run at that frequency for the parts near the node.

Products that fail vibration almost always fail at a resonance, and the failure is a fatigue crack at a joint, a screw that backs out, or a connector that frets. Knowing the frequency tells you where to look.

Why the fixture decides the result

  • Fixture resonance below 55 Hz means the product sees the fixture’s motion, not the specified motion. Stiffen it or raise its first mode above the top of the range.
  • Bolted joints with soft washers absorb energy and reduce the level at the product by several decibels.
  • An accelerometer on the table only controls the table and says nothing about the product.

After the run

Repeat the low-level sweep and compare the transmissibility curve with the one taken before. A resonance that has moved by more than a few percent, or a peak that has dropped, means something has loosened or cracked. Then do the functional and dielectric checks: a product can pass the visual inspection and fail insulation resistance because a terminal has fretted loose.

Record the mounting, the axes, the sweep rate, the accelerometer positions and both sweep curves. A vibration test system with a rigid fixture plate and two control channels is what makes the difference between a certificate and a measurement, and the site index lists the shaker sizes by force rating.

Standards referenced: IEC 60068-2-6.

Contact Us

Contact: Eason Wang

Phone: +86-13751010017

Tel: +86-755-33168386

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

close