2026-11-17
Most small electrical products are vibration tested with a sweep from 10 Hz to 55 Hz and back, repeated for two hours on each of three axes. The numbers look arbitrary until you notice what they cover: the range where a chassis, a terminal block and a DIN rail all have resonances, and the range a road vehicle excites most strongly.
The test is easy to pass and easy to pass wrongly. A product clamped to a table that flexes at 30 Hz is being tested at 30 Hz by the table, not by the specification.
| Parameter | Typical value | Effect |
| Frequency range | 10 Hz to 55 Hz, or 10 Hz to 150 Hz | Covers chassis and mounting resonances |
| Amplitude | Displacement below the crossover, acceleration above | The crossover is where the two are equal |
| Sweep rate | One octave per minute | Too fast and a sharp resonance is missed |
| Duration | 2 hours per axis, 6 hours total | Fatigue, not just survival |
| Axes | Three, orthogonal | A part can be strong in two directions |
| Mounting | As in service, or on a rigid fixture | Decides what is actually excited |
The crossover matters because below it the shaker is displacement-limited and above it acceleration-limited. A specification written only as acceleration will over-test at low frequency; one written only as displacement will destroy the shaker at high frequency.
Run a low-level sweep first, at a tenth of the specified amplitude, with an accelerometer on the product as well as on the table. The ratio between the two curves is the transmissibility, and its peak is where the product will be stressed. If the peak is at 32 Hz with a transmissibility of 8, the 2 hour run is really a 16 hour run at that frequency for the parts near the node.
Products that fail vibration almost always fail at a resonance, and the failure is a fatigue crack at a joint, a screw that backs out, or a connector that frets. Knowing the frequency tells you where to look.
Repeat the low-level sweep and compare the transmissibility curve with the one taken before. A resonance that has moved by more than a few percent, or a peak that has dropped, means something has loosened or cracked. Then do the functional and dielectric checks: a product can pass the visual inspection and fail insulation resistance because a terminal has fretted loose.
Record the mounting, the axes, the sweep rate, the accelerometer positions and both sweep curves. A vibration test system with a rigid fixture plate and two control channels is what makes the difference between a certificate and a measurement, and the site index lists the shaker sizes by force rating.
Standards referenced: IEC 60068-2-6.
Contact: Eason Wang
Phone: +86-13751010017
Tel: +86-755-33168386
Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China