Salt mist is the test everybody asks for and the test most often misread. A part that shows rust after 24 hours has not necessarily failed, and a part that shows nothing after 96 hours has not necessarily passed. The test produces a condition; the verdict comes from the product standard, and the two are frequently confused.
What the test does control precisely is the environment. Four parameters define it, and all four have to be recorded for the result to mean anything.
| Parameter | Value | Consequence if wrong |
| Sodium chloride concentration | 5 % ± 1 % by mass | Changes corrosion rate non-linearly |
| Chamber temperature | 35 °C ± 2 K | Sets the reaction rate and the evaporation |
| pH of the solution | 6.5 to 7.2 | Acidic solution attacks far faster |
| Exposure duration | 24 h, 48 h or 96 h, by product standard | Durations are not interchangeable |
| Salt deposition rate | Set by the spray rate, checked by collectors | A dry fog is not a salt mist test |
| Angle of the specimen | 20 degrees from vertical, typically | Flat surfaces pool and give false results |
The deposition rate check is the one that separates a real chamber from a box with a nozzle. Collectors placed in the chamber must gather a specified volume per unit area per hour; if they do not, the chamber is running a humidity test with salty water, and the result will be optimistic.
Corrosion is not linear in time. A protective layer that forms in the first hours can slow attack, while a coating that fails at a defect will accelerate once the base metal is exposed. That is why 24 hours and 96 hours are different tests rather than two points on one curve, and why a supplier who reports "passed salt spray" without the duration has reported nothing.
The same applies to cycles. Continuous exposure and cyclic exposure (wet, dry, wet) produce different failure modes: continuous tends to general attack, cyclic tends to crevice and undercut attack at edges.
Record the type of attack, not just its presence: white rust on zinc, red rust on steel, blistering of paint, creep of corrosion from a scribe. Measure the width of creep from a scribed line in millimetres, and the area fraction affected. Those two numbers are comparable between laboratories; "some corrosion" is not.
Then check the clause that applies. A product standard may allow red rust on 5 percent of the area after 48 hours and none after 24. Without that clause, a photograph and a duration are not a result. A salt mist chamber with calibrated collectors and a documented deposition rate is the minimum for a defensible report, and the site index lists the chambers by internal volume.
Standards referenced: IEC 60068-2-11; ISO 9227.