Two probes model an adult finger: probe 11, which is a straight 12 mm rod, and probe B, which is the same rod split into jointed segments. They are often treated as interchangeable, and they answer different questions.
Both have a 12 mm working diameter and both carry a 50 mm stop disc of 5 mm thickness. The difference is articulation: probe 11 is rigid, probe B bends at two joints through 90 degrees.
Probe 11 represents a finger held straight and pushed into an opening. Probe B represents a finger that can curl, following a path that turns inside the enclosure.
| Probe | Working part | Reaches |
|---|---|---|
| 11 | 12 mm straight, 80 mm | straight-line paths only |
| B | 12 mm jointed, 80 mm | straight and curved paths |
A rigid probe applies force without folding. When the question is whether a component can be deflected — a flap, a shutter, a flexible cover — the rigid probe transmits the whole force to the point of contact.
A jointed probe under the same force bends at the joint instead of pressing, so the deflection is less and the conclusion can be wrong in the permissive direction.
This is why the rigid probe is the correct tool for assessing whether a protective flap can be pushed aside, and the jointed one is the correct tool for asking how far a finger can travel inside.
Behind a lip. A finger entering an opening and then curling around an internal barrier reaches a region that no straight rod can touch. The rigid probe stops at the barrier and reports no access.
Along a curved channel. A moulded duct that turns 90 degrees admits a finger but not a rod, and the hazard at the far end is only discovered with the jointed probe.
Into a recess with an overhang. The rod enters vertically until the overhang stops it; the finger can bend and continue.
Both probes are used at the force specified by the product standard, commonly 10 N for ingress protection and 30 N for shock-hazard assessment. The jointed probe needs the force applied gradually, because a rapid push folds the joints before the tip reaches position.
A rigid probe has no such limitation, which is another reason the two are not interchangeable: the same test procedure produces different actual loading.
Both, where the product has both straight and curved access paths. A report that says "test finger applied" without naming the probe has left the reader unable to tell which question was answered.
On products where only one is used, the choice itself should be justified: straight access and rigid barriers call for probe 11; internal cavities and overhangs call for probe B.
Probe 11 has no joints, so its failure modes are bend, wear and stop-disc damage. Probe B adds joint play, damping and plane alignment, and it is the joint that fails first.
A rigid probe that has been bent is usually obvious, because the bend shows against a straightedge. A jointed probe that has developed play is not obvious at all, which is why it needs a functional check rather than a visual one.
Probe identity, force, and the access path tested. Where a product was tested with both, record both results separately rather than merging them into one verdict — a product that passes the jointed probe and fails the rigid one has a specific problem with a specific mechanism, and merging the results hides it.