Test probe 13 is the least understood probe in common use. It looks like a small cone on a disc, it is about the size of a pencil tip, and it is specified for a narrow purpose: checking that hazardous live parts of Class 0 and Class II equipment are not accessible through openings that a finger cannot reach.
The probe is a cone of roughly 3 mm to 4 mm across, mounted on a 25 mm stop face. The cone tapers to a blunt point. It is not a pin and it is not a sphere — the taper is the point, because a tapered tip wedges into an opening and stops where the opening narrows to its own diameter, whereas a pin would pass straight through a slot.
The 25 mm stop face does the same job as the larger faces on probes 11 and 12: it fixes the insertion depth so that two operators testing the same product reach the same depth.
The distinction is about what the probe is allowed to touch. On Class I equipment, protection relies on earthing, so the requirement is about basic insulation and clearances that a finger could reach. On Class 0 and Class II equipment there is no earth path and often no second layer of insulation at the point of contact, so the accessibility requirement is stricter: openings that a 12 mm finger cannot enter are still checked, because a thin conductive object could reach through them.
That is where probe 13 comes in. It tests the openings that are too small for a finger but large enough for a wire or a tool tip.
| Probe | Approximates | Applied to |
|---|---|---|
| 11 (12 mm rod, 50 mm face) | adult finger, straight | general accessibility |
| 12 (4 mm rod, 25 mm face) | thin tool or wire | small openings |
| 13 (cone, 25 mm face) | tapered conductive object | Class 0 / Class II parts |
Using probe 13 on a Class I product. This is the most common error, and it comes from treating the probe set as a checklist rather than a set of specific tests. Testing a Class I enclosure with probe 13 produces a fail that has no standing, and a report that cannot be defended.
Pushing past the stop face. The 25 mm face defines the depth. A probe pressed until the cone deforms is testing the deformation, not the opening. The force is applied along the axis, and the reading is taken when the face contacts the enclosure.
Confusing probe 13 with a pin. Probe 13's cone stops at the point where the opening matches its diameter; a pin of the same nominal size would pass through a slot of the same width. The cone is deliberately not a pin, and substituting one changes the test.
"Probe 13, not accessible" is nearly useless six months later. A record that names the standard clause, the product class, the opening tested (with a photograph), the applied force, and the observed result can be repeated by anyone. The extra minute of writing is the difference between a test and an assertion.
One more point that is easy to miss: probe 13 is specified for parts that are hazardous live, not for all metal parts. A metal screw head that is earthed, or that carries only safety extra-low voltage, is not a probe 13 target. Reading the clause before reaching for the probe prevents most of the arguments.