Technical Articles

Test Probe 17: The Half-Millimetre Pin and the Openings It Was Made For

2026-11-23

Test probe 17 is the smallest probe in common use. A 0.5 mm pin, mounted on a body that provides a defined insertion depth, used to answer a question that the larger probes cannot: is a hazardous live part reachable through an opening so narrow that nothing else fits?

What the probe looks like and why

The working end is a pin of about half a millimetre in diameter. It is not sharpened to a point — the end is a small radius — because the intent is to model a thin wire or a component lead, not a needle. The body behind the pin is wider and acts as the stop, so the pin cannot be pushed deeper than the standard intends.

The size is chosen from a specific worry: a stray strand of wire, a lead from a component, a piece of metal swarf. None of those need an opening larger than a millimetre to enter, and all of them can carry enough current to matter.

ProbeWorking sizeModels
170.5 mm pina thin wire or lead
124 mm roda small tool or finger tip
1112 mm rodan adult finger

Where probe 17 applies

It is used where the product standard asks specifically for it, typically on equipment where small openings exist near live parts: ventilation slots, seams between mouldings, connector recesses, the gap around a switch actuator.

It is not a general-purpose probe and should not be used as one. Applying it everywhere produces failures that the standard never asked about, and a report full of such failures is a report nobody trusts.

Three practical difficulties

The pin bends. A 0.5 mm pin is thin enough that a slight side load bends it permanently. A bent pin no longer points where the operator aims it, and on a slot the size of the pin, that is the difference between entering and not. Check straightness by rolling the pin on a flat surface; a bent pin wobbles.

The pin is hard to see. At 0.5 mm the tip disappears against a dark moulding. Good lighting and a contrasting background are not luxuries here — they are what makes the test repeatable.

Contact is hard to judge. When the pin touches a live part, the operator feels almost nothing. Some labs use an electrical indication instead of feel: the probe is connected to a detector, and contact is confirmed by the circuit rather than by the hand. That is more repeatable and worth the extra setup.

What a result means

A probe 17 "not accessible" result is a statement about a 0.5 mm path. It does not say the enclosure is sealed against dust, and it does not say a larger object cannot enter — those are different probes and different questions.

Conversely, a probe 17 "accessible" result on a live part is a genuine finding. It means a thin conductor can reach a hazardous voltage, which is exactly the failure mode the probe was designed to catch. That result should be recorded with a photograph and the location of the opening, because it is the kind of finding that gets argued about later.

Care and inspection

Check the pin diameter with a micrometer at two points, check straightness by rolling, and check the tip radius under magnification. A tip that has been flattened by contact with a hard surface is no longer a 0.5 mm probe in the sense the standard means, even if the diameter still measures correctly.

Store it in a rigid tube. A pin this size does not survive a drawer.