2026-11-23
Test probe 17 is the smallest probe in common use. A 0.5 mm pin, mounted on a body that provides a defined insertion depth, used to answer a question that the larger probes cannot: is a hazardous live part reachable through an opening so narrow that nothing else fits?
The working end is a pin of about half a millimetre in diameter. It is not sharpened to a point — the end is a small radius — because the intent is to model a thin wire or a component lead, not a needle. The body behind the pin is wider and acts as the stop, so the pin cannot be pushed deeper than the standard intends.
The size is chosen from a specific worry: a stray strand of wire, a lead from a component, a piece of metal swarf. None of those need an opening larger than a millimetre to enter, and all of them can carry enough current to matter.
| Probe | Working size | Models |
|---|---|---|
| 17 | 0.5 mm pin | a thin wire or lead |
| 12 | 4 mm rod | a small tool or finger tip |
| 11 | 12 mm rod | an adult finger |
It is used where the product standard asks specifically for it, typically on equipment where small openings exist near live parts: ventilation slots, seams between mouldings, connector recesses, the gap around a switch actuator.
It is not a general-purpose probe and should not be used as one. Applying it everywhere produces failures that the standard never asked about, and a report full of such failures is a report nobody trusts.
The pin bends. A 0.5 mm pin is thin enough that a slight side load bends it permanently. A bent pin no longer points where the operator aims it, and on a slot the size of the pin, that is the difference between entering and not. Check straightness by rolling the pin on a flat surface; a bent pin wobbles.
The pin is hard to see. At 0.5 mm the tip disappears against a dark moulding. Good lighting and a contrasting background are not luxuries here — they are what makes the test repeatable.
Contact is hard to judge. When the pin touches a live part, the operator feels almost nothing. Some labs use an electrical indication instead of feel: the probe is connected to a detector, and contact is confirmed by the circuit rather than by the hand. That is more repeatable and worth the extra setup.
A probe 17 "not accessible" result is a statement about a 0.5 mm path. It does not say the enclosure is sealed against dust, and it does not say a larger object cannot enter — those are different probes and different questions.
Conversely, a probe 17 "accessible" result on a live part is a genuine finding. It means a thin conductor can reach a hazardous voltage, which is exactly the failure mode the probe was designed to catch. That result should be recorded with a photograph and the location of the opening, because it is the kind of finding that gets argued about later.
Check the pin diameter with a micrometer at two points, check straightness by rolling, and check the tip radius under magnification. A tip that has been flattened by contact with a hard surface is no longer a 0.5 mm probe in the sense the standard means, even if the diameter still measures correctly.
Store it in a rigid tube. A pin this size does not survive a drawer.
Contact: Eason Wang
Phone: +86-13751010017
Tel: +86-755-33168386
Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China